Deviation analysis and treatment of 580m2 ring cooler in Jingtang sintering plant
XIANG Bao-sheng1,LI Jian-xiong2
(1. Equipment Department, Shougang Jingtang United Iron and Steel Co., Ltd., Tangshan 063200, Hebei, China 2. Ironmaking Department, Shougang Jingtang United Iron and Steel Co., Ltd., Tangshan 063200, Hebei, China)
Abstract:The ring cooler adopts the 580m2 ring cooling blasting type in Jingtang sintering plant,which was used to cool the sinter. The sinter cooling is an important part of sinter process. Whether the ring cooler is stable will cause a huge impact to the sintering yielding. By analyzing the cause of No.2 ring cooler deviation fault and the impact,the swing frame is measured and adjusted repeatedly. By using the effective treatment,the question of ring cooler deviation is solved,the impact that is caused by the deviation is absolutely curbed.