Treatment and numerical simulation for cooling water pipe damage of blast furnace cooling stave |
LI Jia1,2,3, CHEN Shuai1,2,3, LUO Shiyuan1,2,3, JIANG Jun1,2,3, ZHANG Zhengdong4, GUO Hongwei5 |
1. Key Laboratory of Metallurgical Equipment and Control of Ministry of Education, Wuhan University of Science and Technology, Wuhan 430081, Hubei, China; 2. Hubei Key Laboratory of Mechanical Transmission and Manufacturing Engineering, Wuhan University of Science and Technology, Wuhan 430081, Hubei, China; 3. Precision Manufacturing Institute, Wuhan University of Science and Technology, Wuhan 430081, Hubei, China; 4. Wuhan Iron and Steel Company Limited, Wuhan 430080, Hubei, China; 5. Shagang School of Iron and Steel, Soochow University, Suzhou 215021, Jiangsu, China |
|
|
Abstract In order to reduce the temperature of the blast furnace shell surface and enhance the utilization efficiency of the blast furnace cooling column,the situation of installing cooling columns when the different cooling water pipes on the blast furnace cooling stave were damaged was analyzed, and the arrangement of one of cooling columns was optimized. At the same time, a new method of plate-column combination was proposed to further reduce the temperature when the stave cooling water pipe were damaged. The numerical simulation results show that when the different cooling water pipes on the cooling stave are damaged, the surface temperature of the furnace shell with the cooling column is significantly lower than that without the cooling column. The cooling column arrangement obtained by genetic algorithm makes the maximum temperature for furnace shell surface of 60.9 ℃ and the average temperature of 48.1 ℃. Compared with the original arrangement in the factory, the maximum temperature of furnace shell surface is reduced by 6.8% and the average temperature is reduced by 4.1%. The maximum temperature at shell surface of the plate-column combination arrangement is 61.4 ℃, and the average temperature is 49.7 ℃. Compared with the original arrangement without cooling plates, the maximum temperature is reduced by 25.2% and the average temperature is reduced by 28.1%. The numerical simulation results can provide theoretical basis for the installation of cooling columns when the cooling water pipe of the cooling stave is damaged.
|
Received: 31 January 2023
|
|
|
|
[1] |
张恒,张建良,焦克新,等. 高炉板壁结合冷却器破损原因解析[J]. 钢铁,2018,53(8):28.
|
[2] |
王新东,郝良元,胡启晨,等. 河钢集团高炉炼铁技术进步[J]. 中国冶金,2020,30(1):73.
|
[3] |
王东,白国成,张永升,等. 承钢2 500 m3高炉铜冷却壁破损的处理[J]. 炼铁,2020,39(4):28.
|
[4] |
吕翠花,牛建平,韩永清,等. 铜钢一体冷却柱在宣钢高炉上的应用[J]. 炼铁,2008,27(4):58.
|
[5] |
张明刚,张江锋. 宣钢2 500 m3高炉安装铜冷却柱及造衬效果分析[J]. 河北冶金,2013(3):36.
|
[6] |
刘悦今,李文斌. 涟钢4号高炉安装圆柱形冷却器实践[J]. 炼铁,2001,20(6):39.
|
[7] |
程素森,杨天钧,杨为国,等. 高炉冷却壁传热分析[J]. 钢铁,2001,36(2):8.
|
[8] |
张恒,张建良,焦克新,等. 铜钢复合冷却壁传热能力及热变形分析[J]. 炼铁,2018,37(1):10.
|
[9] |
郑建春,宗燕兵,苍大强. 高炉铜冷却壁热态实验及温度场数值模拟[J]. 北京科技大学学报,2008,30(8):938.
|
[10] |
陈帅,李佳,罗石元,等. 高炉冷却柱的设计优化与数值模拟[J]. 钢铁,2022,57(7):34.
|
[11] |
李继昌,张运鸿,王庆学. 冷却柱技术引进与自主开发实践[J]. 甘肃冶金,2012,34(6):1.
|
[12] |
陈子文,王彦哲,陈可. 基于蒙特卡洛法的大风区接触网系统可靠性分析[J]. 电气化铁道,2022,33(5):36.
|
[13] |
刘顺娣,李宝宽,于洋,等 直流矿热炉熔炼硅锰合金温度场-电磁场数值模拟[J]. 中国冶金,2022,32(1):104.
|
[14] |
陈正阳,杨树峰,谢锦丽,等. 钛合金异形薄壁壳体铸造工艺数值模拟及优化[J]. 中国冶金,2022,32(10):105.
|
[15] |
庞传彬,袁飞,徐安军,等. 转炉炼钢出钢过程的数值模拟[J]. 中国冶金,2022,32(9):8.
|
[16] |
薛瑞,张燕超,张彩军,等. 160 mm×160 mm小方坯连铸结晶器内流场数值模拟[J]. 中国冶金,2020,30(1):51.
|
[17] |
陈庆安,张建宇,王艳辉,等. 方坯直轧工艺中头尾温差消除过程数值模拟[J]. 中国冶金,2019,29(9):23.
|
[18] |
薛庆国,高小武,程素森. 冷却壁高炉炉墙温度场的数值模拟(I)──耐火材料种类及其侵蚀程度对炉墙温度场的影响[J]. 北京科技大学学报,2000,22(2):127.
|
[19] |
MOHANTY T R,SAHOO S K,MOHARANA M K. Computational modeling of blast furnace stave cooler based on steady state heat transfer analysis[J]. Procedia Engineering,2015,127:940.
|
[20] |
郑源斌,蒋朝辉. 高炉铜冷却壁温度场数值模拟及其挂渣分析[J]. 有色冶金设计与研究,2014,35(4):1.
|
|
|
|